The cause of 80% of the malfunctions in hydraulic systems is hydraulic oil pollution. With an effective filtration system, it is possible to reduce sudden stops and malfunctions by 80%. Contamination of hydraulic fluids can seriously damage components in hydraulic systems. With early detection and intervention, you can save time, especially cost. Contaminated hydraulic oil is often the first sign of a machine failure. In hydraulic systems, flushing and filtration are very important because the most important factor in the smooth operation of the system is the cleanliness of the system. We can explain this concept of cleaning by the fact that a hair of a person is 90 micron, the smallest particle that the best eye can see is 40 microns, in hydraulic systems it is 20 microns, and even in systems with proportional valves 10 microns or more are the cause of failure.
With the Seide RK91 Mobile Filtration and Flushing Machine, the filter elements in the return line of the flushing circuit in the system will be made by using 60 micron filter elements at first, then 25 micron, and at the last step 10 micron filter elements. The last stage filter element has a 5 micron element option for more sensitive cleaning. Particles can be counted with an electronic pollution measuring device for pollution measurement in the system. Direct connection can be made with minimes connection on the lines. Written report is obtained with the measurements made with this device. It specifies the number of parts in different diameters from 2 microns to 100 microns and accordingly the corresponding NAS and ISO standards.
FLUSHING IN HYDRAULIC SYSTEMS In hydraulic systems, flushing is the cleaning process that takes place by circulating the hydraulic oil to be used later in the system in the pipes. In a closed volume, the oil must create friction in the pipe or hose in order to circulate the oil and clean the particles. The friction of the oil in the pipe occurs when the oil flow turns from laminar flow to turbulent flow.
WHY CHOOSE SEIDE RK91 Seide RK91 is a system where you can perform flushing at the same time with high flow or more oil filtration. In this model, the pump flow rate is 80 lt/min. The electric motor of the units can be 230 VAC single-phase or 400 VAC three-phase. RK91 series units 900 gr. with its dirt holding capacity comes out. With the Seide RK91 model, 3-stage filtration and flushing are applied to ensure hydraulic system cleaning at 60 micron, 25 micron and 10 micron levels, respectively. In addition, a 5 micron filter element can be used optionally. Each of the 3-stage filters has a permeability of 950 lt/min, reducing the cost of filter replacement and providing 400% economic use compared to equivalent products.
MEASUREMENT RESULTS WITH PARTICLE COUNTER It is very important to clean the hydraulic oil regularly and to check the pollution level so that it does not cause malfunctions. You can do these applications with Seide RK91 Mobile Filtration and Flushing Machine without stopping your existing hydraulic equipment system. You can carry out simultaneous predictive maintenance work without degrading the performance of your hydraulic system.
Advantages of Hydraulic Filter Machine
Productivity Make sure the oil is completely free of all particles with the three-stage filtration system. Economic It provides a better filtration that extends the lifetime of the machines as much as possible. For this reason, it eliminates frequent maintenance and part replacement costs. Compact Design The machine can be easily transported to any location in any condition, with its compact design improved by the solidity of the chassis and its curved lines. Fixing the Hoses The machine can be easily transported to any location in any condition, with its compact design improved by the solidity of the chassis and its curved lines. Final and Guaranteed Result The desired oil and pollution level is measured with the particle counting device whose calibration is already available, and precise and guaranteed results are obtained. Pollution Control Particles can be counted with an electronic pollution measuring device. Direct connection can be made with minimes connection on the lines. Written report is obtained with the measurements made with this device.